Ana Sayfa >>>                                      El tipi dürbün refraktometre/ El refraktometre

Kullanım Alanları : Sıvı malzemelerin içindeki katı madde miktarını brix cinsinden ölçmeye yarayan el refraktometresidir.

Sektörler : Kimya , Süt, Meyve Suyu, Tutkal, Aroma , Bal, Tuz, Akü sıvıları, Antifreeze,Alkol,Şarap, Meşrubat,Deterjan,Salça,vs....

 

 

 

 

 

Brix (Seker) Refractometer

RHB serisi refraktometre şeker içeren sıvı ve likitlerin içindeki katı madde miktarını ölçne cihazlardır, Meyve suyu,yumuşak içecekler,şarap , bal vs tipi malzemeleri ölçmeye yarar .

 

Model

Range

Min.Div.

Accuracy

Remark

RHB0-80

Brix: 0-80%

Brix: 0.5%

Brix: ±0.5%

Without Atc

RHB-32

Brix: 0-32%

Brix: 0.2%

Brix: ±0.20%

Without Atc

RHB-32ATC

Brix: 0-32%

Brix: 0.2%

Brix: ±0.20%

Atc

RHB-32-Oe

Brix: 0-32% 
Oe: 0-140°

Brix: 0.2%
1.0° Oe

Brix: ±0.20% 
±1.0° Oe

Without ATC

RHB-32-OeATC

Brix: 0-32% 
Oe: 0-140°

Brix: 0.2%
1.0° Oe

Brix: ±0.20% 
±1.0° Oe

Atc

RHB-32-K

Brix: 0-32% 
Oe: 0-140°
0-25 KMW

Brix: 0.2%
1.0° Oe
0.2 KMW

Brix: ±0.20% 
±1.0° Oe
±0.2 KMW

Without Atc

RHB-32-K-ATC

Brix: 0-32% 
Oe: 0-140°
0-25 KMW

Brix: 0.2%
1.0° Oe
0.2 KMW

Brix: ±0.20% 
±1.0° Oe
±0.2 KMW

Atc

RHB-55

Brix: 0-55%

Brix: 1%

Brix: ±1%

Without Atc

RHB58-92

Brix: 58-92%

Brix: 0.2%

Brix: ±0.2%

Without ATC

RHB-62

Brix: 28-62%

Brix: 0.2%

Brix: ±0.20%

Without Atc

RHB-62ATC

Brix: 28-62%

Brix: 0.2%x

Brix: ±0.2%

Atc

RHB-82

Brix: 45-82%

Brix: 0.5%

Brix: ±0.50%

Without Atc

RHB-82ATC

Brix: 45-82%

Brix: 0.5%

Brix: ±0.5%

Atc

RHB-90

Brix: 58-90%
Baume: 38-43Be'
water: 12-27%

Brix: 0.5%
Baume: 0.5Be'
water: 1%

Brix: ±0.5%
Baume: ±0.5Be'
water: ±1%

Without Atc 

RHB-90ATC

Brix: 58-90%
Baume: 38-43Be'
water: 12-27%

Brix: 0.5%
Baume: 0.5Be'
water: 1%

Brix: ±0.5%
Baume: ±0.5Be'
water: ±1%

Atc

 

                                                                Tuz (Salt )  Refraktometre

The RHS series are designed for testing the concentration of salt water and brine. Provides a direct reading of the specific gravity and concentration (Parts Per Thousand) of salt in water. It provides reliable refractive index and salinity readings of total dissolved solids of aqueous solutions. It is used for quality control in research and clinical laboratories. It can be used to check and maintain stock solutions and dilutions. In the food industry, it is especially effective in the preparation of frozen vegetables, fruits, seafood and ocean byproducts. The Salinity Refractometer is also used in oceanography and seawater studies for determining soil quality. The model having ATC (Automatic Temperature Compensation) is ideal for field use.

Model

Range

Min.Div.

Accuracy

Remark

RHS-10

0-100 PPT
1.000-1.070 SG

1.0 PPT
0.001 SG

±1.0 PPT
±0.001 SG

Without ATC

RHS-10ATC

0-100 PPT
1.000-1.070 SG

1.0 PPT
0.001 SG

±1.0 PPT
±0.001 SG

ATC

RHS-28

0-28%

0.20%

±0.20%

Without ATC

RHS-28ATC

0-28%

0.20%

±0.20%

ATC

 

Şarap (Wine) Refractometer

The RHW series are developed for working with alcohol or sugar related wines and concentration of alcohol. It can measure the alcohol concentration in wines or water solution. And it also is developed for measuring the sugar in the grapes, that helps the manufacturer to decide the best time to manufacture the grape wine

Model

Range

Min.Div.

Accuracy

Remark

RHW-25

0-25%Vol
0-40%Brix

0.20%Vol
0.20%Brix

±0.2%Vol
±0.2%Brix

Without ATC

RHW-25ATC

0-25%Vol
0-40%Brix

0.20%Vol
0.20%Brix

±0.2%Vol
±0.2%Brix

ATC

RHW-25-Be

0-25%Vol
0-20Be°

0.20%Vol
0.20Be°

±0.2%Vol
±0.2%Be°

Without ATC

RHW-25ATC-Be

0-25%Vol
0-20Be°

0.20%Vol
0.20Be°

±0.2%Vol
±0.2%Be°

ATC

RHW-80

0-80%Vol

Varies

±1%

Without ATC

RHW-80ATC

0-80%Vol

Varies

±1%

ATC

 

Antifiriz / Battery / Antifreeze/Battery/Cleaning Fluids Refraktometre

The RHA series are designed to test the concentration of the battery fluids, antifreeze liquid and cleaning fluids. With the indication of the percentage you may know at which temperature the fluid will be frozen for both propylene glycol and ethylene glycol. It can also be used for checking the strength of electrolyte solution batteries. Remarks: in the following firms, E, P, B and C respectively refer to ethylene Glycol, Propylene Glycol, Battery and Cleaning Fluids.

Model

Range

Min.Div.

Accuracy

Remark

RHA-100

E:-84°F-32°F
P:-60°F-32°F
B:1.100-1.400sg

5°F
5°F
0.01sg

±5°F
±5°F
±0.01sg

Without ATC

RHA-100ATC

E:-84°F-32°F
P:-60°F-32°F
B:1.100-1.400sg

5°F
5°F
0.01sg

±5°F
±5°F
±0.01sg

ATC

RHA-200

E:-60°C-0°C
P:-50°C-0°C
B:1.100-1.400sg

5°C
5°C
0.01sg

±5°C
±5°C
±0.01sg

Without ATC

RHA-200ATC

E:-60°C-0°C
P:-50°C-0°C
B:1.100-1.400sg

5°C
5°C
0.01sg

±5°C
±5°C
±0.01sg

ATC

RHA-300F

E:-60°F-32°F
P:-50°F-32°F
B:1.15-1.30sg

10°F
10°F
0.01sg

±10°F
±10°F
±0.01sg

Without ATC

RHA-403C

E:-50°C-0°C
P:-50°C-0°C
C:-40°C-0°C
B:1.15-1.30sg

5°C
5°C
5°C
0.01sg

±5°C
±5°C
±5°C
±0.01sg

Without ATC

RHA-501

E:-90°F-32°F
E:-70°C-0°C
P:-70°F-32°F
P:-60°C-0°C
B:1.100-1.400sg

10°F
5°C
10°F
5°C
0.01sg

±10°F
±5°C
±10°F
±5°C
±0.01sg

Without ATC

RHA-503C

E:-50°C-0°C
P:-50°C-0°C
C:-40°C-0°C
B:1.100-1.400sg

5°C
5°C
5°C
0.01sg

±5°C
±5°C
±5°C
±0.01sg

Without ATC

 

Klinik Protein Refraktometre

 

The RHC series are designed for clinical usage and intended for both Veterinary and Human Being. This unit provides veterinarians and Human Being with quick and accurate indication of vital fluids' levels. Its triple scale reads Total Serum Protein, Refractive Index and Urine Specific Gravity

.

 

Model

Range

Min.Div.

Accuracy

Remark

RHC-200

0-12g/100ml
1.330-1.360RI
1.000-1.050sg

0.2g/100ml
0.0005RI
0.005sg

±0.2g/100ml
±0.0005RI
±0.005sg

Without ATC

RHC-200ATC

0-12g/100ml
1.330-1.360RI
1.000-1.050sg

0.2g/100ml
0.0005RI
0.005sg

±0.2g/100ml
±0.0005RI
±0.005sg

ATC